In this article, we will cover the following;
Product OverviewHere is an OXY-LC Interface Board At the right-hand side of this board you will see 5 pin connections, numbered 1 to 5, these are where the sensor wires will be connected. |
To ensure the best performance the best performance from your O2 probe and interface board, it must be installed correctly. Always handle the interface board using the correct ESD handling precautions.
During installation, to prevent contamination and poisoning the following must be considered:
When connecting the sensor and board, to prevent electrical damage and mechanical damage, the following must be considered:
It is necessary to complete the following BEFORE switching the system ON for the first time:
Apply a 24 VDC power supply and test the power supply to ensure it is delivering the correct voltage before wiring the device. Failure to do so BEFORE first power on could result in irreversible product damage that is NOT covered by warranty.
When the device is initially powered on, the status of the sensor and board should read the following; communication OK, supply current is normal (<1 A) and there is a valid O2% reading after 1 minute.
During test, you should expect to see the following readings from each output:
If a fault it detected, an error code is displayed (RS485 variant), or the analogue output will remain at 4 mA or 0 V.
We recommend housing the interface board in a suitable enclosure to protect from damage. The interface must be securely fitted to a suitable mounting surface using the mounting holes provided. Protect the interface from accidental shocks or vibrations as this may damage the board. |