Low Power Dual-Gas Methane/Carbon Dioxide Infrared sensors

Low Power Dual-Gas HC + CO2 Infrared Sensors


Key features

  • 15mA / 45mW at 3V power consumption
  • 1mA saving when compared to 2 LP2 Sensors
  • Industrial Ex d IIC Certified, Mining M1 Certified available for all variants
  • EN50271 / SIL1 certification available for all variants.
  • All sensors carry a 5-year warranty
  • Measures methane from 0 -100% volume with a resolution of 0.01 % for 0-5% methane and 0.1% for 5-100% volume
  • Measures Propane from 0 -2% volume with a resolution of 0.01% volume
  • Multiple gas ranges enable the accurate detection of 0-100% vol. methane, 0-2% vol. propane and 0-100% vol. carbon dioxide with one sensor
  • Measures carbon dioxide from 0 to 5% volume with a resolution of 0.01 % and 0.1% for 5-100% volume
  • Configuration available specifically for biogas measurement
  • User configurable using USB powered Premier Configuration Unit
  • Internal Flash memory allowing sensor firmware updates via configuration unit
  • Enhanced EMC protection
  • Infrared NDIR Sensor

Overview

Our Low Power Dual-Gas Methane (CH4) / Carbon Dioxide (CO2) sensors are revolutionary devices for the simultaneous measurement of Methane and Carbon Dioxide in a single sensor package. They achieve this whilst only consuming the power of a single infrared sensor. The sensors also have the additional benefit of a pre-characterised 0-2% Propane measurement range included as standard.

The sensors provide accurate measurement of gas levels using infrared gas sensing techniques. Various versions are available with combinations of ranges up to 100% volume Methane and 5% volume Carbon Dioxide. They consume the power of a single infrared sensor and therefore provide prolonged battery life when used within portable gas detectors.

The Hydrocarbon channel provides simultaneous readings for both High Resolution Methane and Propane.

  • Hydrocarbon Channel Resolution - 0.01% for range 0 to 10% Vol. and 0.1% for range 10% to 100% Vol. (CH4)
  • Carbon Dioxide Channel Resolution - 0.01% Vol. (CO2)
  • The sensors are part of the 'Platinum' Series and are available in Industrial Ex d IIC Certified, Mining M1 Certified and Non-Certified versions. They are also UL approved.


    The 'Premier' Gas Sensor Configuration unit is for use with 'Platinum' Series sensors. It enables customisation of user definable parameters, data logging and calibration.

    Resources

    Come and meet us.

    Contact us or Request a Quote